Introduction
AS/NZS 4994.1 is an important standard for temporary edge protection systems used on construction sites in Australia and New Zealand. Its 2023 edition replaces the 2009 edition, introducing updates to the scope, system configurations, product information, design requirements and testing provisions.
For construction contractors, scaffolding companies, equipment distributors and edge protection manufacturers, understanding these changes is important when selecting, supplying or specifying temporary edge protection equipment.
But what has actually changed between the two editions? Do existing systems designed and tested to the 2009 edition still meet the updated requirements? And what should buyers check when sourcing edge protection systems?
This guide compares AS/NZS 4994.1:2009 and AS/NZS 4994.1:2023, focusing on the technical changes and their practical implications for manufacturers and buyers.

1. Understanding AS/NZS 4994.1:2009 and 2023
AS/NZS 4994.1 is titled Temporary Edge Protection – Part 1: General Requirements.
The 2009 edition established requirements for the design, manufacture and testing of temporary edge protection equipment. It covered roof edges with slopes not exceeding 35° to the horizontal, as well as other exposed edges before permanent walling materials were installed.
The 2023 edition is the second edition of the standard. It retains the original technical framework while expanding and clarifying several requirements.
According to its preface, the major changes include:
- A revised scope that includes AS/NZS 4994.4.
- Expanded configuration requirements addressing material conveyors.
- Updates to the testing appendices to improve clarity.
The 2023 edition also provides more detailed requirements for product information, access arrangements, infill panels and system configurations.
AS/NZS 4994.1:2009 vs 2023: Key Changes at a Glance
| Area | 2009 Edition | 2023 Edition |
| Scope | Design, manufacture and testing | Revised to include installation |
| Product information | Basic product and installation documentation | Adds reinspection frequency for installed systems |
| Material conveyors | No equivalent detailed provisions | Specific requirements introduced |
| Flexible materials | Restricts chains, ropes and steel wire strands for roof edge protection | Explicitly extends the restriction to other flexible materials, including reinforced fabric |
| Infill panels | Existing structural and non-structural panel classifications | Further requirements for mesh apertures and wind loads |
| Personnel access | Less detailed provisions | More specific access and gate requirements |
| Roof guardrail inclination | No equivalent general 20° limit | Maximum 20° inclination away from the roof from vertical |
| Essai | Original static and dynamic testing framework | Revised and clarified testing provisions, including gates |
The following sections explain the changes in more detail.
2. Changes in Scope and Application
One of the important updates in the 2023 edition is the revised scope.
The 2009 edition applied to temporary edge protection equipment used on roofs with slopes not exceeding 35° and other exposed building edges.
The 2023 edition retains the 35° roof slope limitation but clarifies its relationship with other parts of the AS/NZS 4994 series.
The updated standard references:
- AS/NZS 4994.2 – Installation and dismantling of roof edge protection.
- AS/NZS 4994.3 – Installation and dismantling of edge protection for other edges.
- AS/NZS 4994.4 – Design, manufacture, installation, repositioning and dismantling of perimeter protection screens.
The 2023 edition also clarifies the use of prefabricated edge protection connected to temporary structures.
Examples include:
- Concrete blocks
- Temporary sheet piles
- Shoring systems
- Formwork systems
This provides a clearer framework for considering temporary edge protection in different construction environments.
What does this mean for buyers?
When selecting an edge protection system, buyers should consider not only the barrier and post but also the supporting structure and attachment method.
For example, a system installed on a concrete slab may require a different fixing arrangement from one installed on a steel beam, sheet pile or formwork structure.
The inclusion of these applications does not mean every attachment configuration automatically complies. Each system still needs appropriate design and verification.
3. Updated Product Information Requirements
The 2023 edition places additional emphasis on the documentation supplied with temporary edge protection equipment.
Both editions require documented product information in plain English and SI units.
Cela comprend :
- Installation and dismantling instructions
- Instructions for use, transportation and storage
- Component identification
- Servicing and inspection guidance
- Procedures for rejecting damaged components
- System limitations and acceptable configurations
- Requirements for supporting structures
However, the 2023 edition specifically adds the frequency of reinspection of installed systems.
It also provides further detail on information relating to supporting components and roof cladding integrity.
This makes product documentation an important part of the overall system specification.
What should a product documentation package include?
For buyers and project teams, a useful documentation package should cover:
- Product installation manual.
- Component identification and specifications.
- Inspection and maintenance instructions.
- Reinspection frequency.
- Maximum post spacing and acceptable configurations.
- Supporting structure requirements.
- Relevant test reports and product limitations.
Manufacturers should make sure that the documentation describes the actual system configurations supplied, rather than relying on generic product descriptions.
4. Changes to Edge Protection Design Requirements
The 2023 edition provides more detailed requirements for certain construction activities and system configurations.
4.1 Material Conveyors and Openings
One of the specific additions concerns material conveyors used near edge protection systems.
Under Clause 3.4.3 of the 2023 edition, where a material conveyor is used:
- The conveyor must not be supported by any part of the roof edge protection system.
- Openings should be as small as practicable while allowing the conveyor to pass.
- When the conveyor is not in use, the edge protection system must be reinstated.
- The material conveyor must be separate from, and must not interfere with, personnel access.
These requirements are relevant to construction sites where materials need to be moved through or across protected edges.
They also highlight the importance of designing openings and removable barrier sections without compromising the overall protection system.
4.2 Structural and Non-Structural Infill Panels
Both editions distinguish between structural and non-structural infill panels.
A structural infill panel transfers design loads directly to supporting posts without requiring backing rails.
A non-structural infill panel relies on backing rails to transfer loads to the supporting posts.
The 2023 edition provides further clarification regarding their performance and use.
For panels intended to prevent materials from falling over the edge, the standard specifies a maximum aperture of 50 mm × 50 mm.
The standard also addresses additional wind loads on infill panels and their supporting structures.
This is particularly relevant when selecting mesh barriers for exposed construction sites.
A mesh panel should not be assessed in isolation. Its supporting posts, rails, connections and overall configuration also need to be considered.
4.3 Toeboards and Material Containment
Toeboards remain an important part of temporary edge protection where additional material containment is required.
The 2023 edition retains the minimum toeboard height of 150 mm and requires sufficient strength and rigidity to prevent a person from passing through.
It also specifies that, where a toeboard is required to prevent materials from falling from the roof, the distance between the underside of the toeboard and its supporting surface must not exceed 10 mm.
This is an important consideration when specifying mesh barriers with integrated or separate toeboards.
4.4 Roof Guardrail Inclination
The 2023 edition introduces a specific requirement for the inclination of roof edge protection.
Roof edge protection must not be inclined away from the roof by more than 20° from the vertical.
Where a system is inclined away from the roof, its design must also ensure that under design loads the system does not deflect towards the roof and allow a person to fall between the rails.
This is relevant when designing roof-mounted and sloping-roof edge protection systems.
5. Personnel Access and Safety Gate Requirements
Personnel access is another area where the 2023 edition provides more specific requirements.
Dedicated access must be provided through roof edge protection where required.
Where access gates are used, they must:
- Open inwards.
- Be self-closing.
- Not open beyond 90° in relation to the guardrailing.
- Provide a minimum clear passage width of 600 mm.
The standard also addresses ladder positioning and securing at the access point.
These provisions are particularly relevant to manufacturers supplying temporary safety gates and access components.
When evaluating a gate system, buyers should consider more than its physical dimensions. Its opening direction, closing mechanism, connection strength and integration with the surrounding barrier system are also important.
6. Design Loads: What Has Stayed the Same?
Although the 2023 edition introduces several design clarifications, the main static load values remain consistent with the 2009 edition.
| Design requirement | 2009 Edition | 2023 Edition |
| Static concentrated load | 600 N | 600 N |
| Uniformly distributed load | 350 N/m | 350 N/m |
| Maximum test load for a post | 1,200 N | 1,200 N |
| Roof slope covered by the standard | Up to 35° | Up to 35° |
| Dynamic testing threshold for roof edge protection | Greater than 15° | Greater than 15° |
The design must also account for dynamic loads, wind actions and other relevant environmental loads.
For manufacturers, an important point is that the load capacity of an individual component does not establish the performance of the complete edge protection system.
The load path needs to be considered from the barrier and post through the attachment and into the supporting structure.
For example, a mesh barrier may perform adequately in isolation, but the connection between its post and a slab grabber or beam clamp must also be suitable for the intended application.
This is why system-level design and testing are important.
7. Supporting Structure Requirements
Both editions require the supporting structure to have sufficient strength and stability to resist the loads transferred by the edge protection system.
The design should identify the minimum dimensions, material grades and attachment positions of the supporting members.
The 2023 edition further clarifies the information required for supporting components.
For example, when specifying an edge protection attachment, the following details should be considered:
- Supporting material: concrete, steel or timber.
- Minimum supporting member dimensions.
- Material grade and strength.
- Attachment position.
- Fixing requirements.
- Acceptable installation configurations.
These details are particularly important for slab-mounted systems, steel beam clamps and other mechanical attachment solutions.
The suitability of an attachment must always be assessed against its intended supporting structure and design loads.
8. Testing Requirements: 2009 vs 2023
The overall testing framework remains based on static and dynamic testing.
The 2023 edition retains the five main testing appendices, while updating and clarifying the testing provisions.
| Appendix | Testing subject |
| Appendix A | Static testing of a post |
| Appendix B | Static testing of rails, infill panels and toeboards |
| Appendix C | Dynamic testing of a post, top rail or structural infill panel |
| Appendix D | Dynamic testing of bottom rails and toeboards |
| Appendix E | Dynamic testing of the centre of a structural infill panel |
The 2023 edition also identifies gates separately in its testing summary table.
This is relevant for manufacturers developing complete access and edge protection systems.
Static Testing
Static testing evaluates the strength and deflection performance of individual components and their connections under specified loads.
The main test forces include:
- 600 N for relevant post and rail tests.
- 1,200 N maximum test load for posts.
- 600 N for specified rail and infill panel tests.
The applicable test direction, position and acceptance criteria depend on the component being tested.
Tests dynamiques
Dynamic testing evaluates the performance of the system under impact loading.
For roof edge protection designed for roof slopes greater than 15° from the horizontal, dynamic testing is mandatory.
Below this angle, the requirement for dynamic testing must be identified by the designer.
A component subjected to a dynamic test does not need to undergo a separate static test for the same application in the same direction.
For buyers, this distinction matters when reviewing test reports. A static test report alone should not be treated as evidence of dynamic performance where dynamic testing is required.
9. Does Your Existing 2009-Compliant System Meet the 2023 Requirements?
This is an important question for contractors, distributors and equipment rental companies that already own temporary edge protection equipment.
A system designed and tested to AS/NZS 4994.1:2009 should not automatically be considered compliant with the 2023 edition.
However, this does not necessarily mean that every existing product needs to be redesigned or retested.
The appropriate approach is to review the existing system against the updated requirements.
Consider the following areas:
- Product configuration
Are the tested post spacing, barrier arrangements, extensions and corner configurations consistent with the current product?
- Connection methods
Have the attachments and supporting structures been included in the relevant design and testing arrangements?
- Infill panels
Do the panel specifications meet the requirements for their intended function, including material containment where applicable?
- Dynamic performance
Does the existing test documentation cover the applicable dynamic loading requirements?
- Access components
If the system includes gates, have the relevant access and testing requirements been addressed?
- Product documentation
Does the documentation include the information required by the 2023 edition, including inspection and reinspection guidance?
A documented gap assessment is a practical first step before deciding whether additional testing or design changes are necessary.
10. What Should Buyers Ask Their Edge Protection Suppliers?
When sourcing temporary edge protection systems for Australian and New Zealand projects, buyers should look beyond the product price and basic specifications.
A reliable supplier should be able to explain how its products are designed, tested and intended to be installed.
Here is a practical checklist:
- Does the supplier provide relevant AS/NZS 4994.1:2023 test documentation?
- Are the tested product configurations clearly identified?
- Are static and dynamic test results available where applicable?
- Are the supporting structure and attachment requirements documented?
- Are installation, inspection and maintenance instructions provided?
- Are product limitations and maximum post spacings clearly stated?
- Are access gates and other system components addressed in the technical documentation?
- Can the supplier support different project requirements through OEM/ODM manufacturing?
These questions can help buyers assess whether a supplier offers a properly documented edge protection system rather than simply individual components.
11. Conclusion
The transition from AS/NZS 4994.1:2009 to AS/NZS 4994.1:2023 represents an important update to the requirements for temporary edge protection in Australia and New Zealand.
While many of the fundamental structural design and testing principles remain, the updated edition provides more detailed provisions for product information, material conveyors, infill panels, personnel access, system configurations and testing.
For manufacturers and buyers, the key takeaway is that edge protection should be evaluated as a complete system.
The performance of barriers, posts, attachments and supporting structures must work together to provide the intended protection.
At APAC Safety, we supply temporary edge protection components and systems for different construction applications, including concrete slabs, steel structures, formwork and other supporting structures.
Looking for an edge protection solution for your next project?
[Contact our team] to discuss product configurations, technical documentation and OEM/ODM manufacturing requirements.